Reg. 519 F, Reg. 519
G, Reg. 519
H
STANDARD CONDITIONS FOR THE DESIGN AND
CONSTRUCTION
OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR
VESSELS
VALVES AND MOUNTINGS
(F) Non-return valves in return feed line |
| Economisers provided
with means for heating the incoming feed by mixing it
with hot water from the economiser outlet must have a
non-return valve in the hot water return line. |
|
| |
Reg. 519
G
STANDARD CONDITIONS FOR THE DESIGN AND
CONSTRUCTION
OF ECONOMIZER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR
VESSELS
VALVES AND MOUNTINGS
Reserve Flues |
| |
| In every case a reserve
flue shall be provided for by passing the flue gases when
no water is being fed to the boiler through the economizer
where it is not integral with the boiler. |
|
| |
Reg. 519
H
STANDARD CONDITIONS FOR THE DESIGN AND
CONSTRUCTION
OF ECONOMIZER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR
VESSELS
VALVES AND MOUNTINGS
Explosion Doors |
| |
| To relieve the economisers
of excessive pressure accumulation due to internal explosion
doors preferably of horizontally hinged self-sealing
type shall be fitted. |
|